Non-contact measurement with ChromaPoint long working distance optical heads
OP SERIES
OP series consists of a one-piece optical sensor head for dedicated applications (e.g. long distance).
The performance and specifications are dedicated to various applications in the industry.
Typically integrated as OEM for measuring 3D shapes, glass thickness, autofocus, OP series fits a wide range of applications.
OP series is designed according to specifications dedicated to identified applications.
Its robot arm is compatible with a long working distance and an extended measuring range.
More than 10 references are optimized in terms of photometric efficiency, working distance and slope angle acceptance to measure non-contact roughness, multi-layer thickness or curved surfaces.
Usually implemented in OEM machines to work in-line in an industrial environment, OP series is the ideal compromise between flexibility, mechanical and optical constraints, performance and price.
It is also ideal for specific applications dedicated to in-line signal acquisition such as thickness measurement of dark bottles.
Customized and adaptable to the widest range of applications and made of passive components, OP series is robust and reliable, and can be used with all STIL controllers such as ZENITH, CCS series, LightMaster or IRIX™.
- Exceptional working distance up to more than half a meter
- Ideal for implementing a specific optical path while respecting mechanical constraints
- Dedicated to industrial environment, independent from ambient light
- High axial resolution: From nanometer scale (nm)
- High photometric efficiency
- High signal to noise ratio
- Works on a large set of materials, including black carbon, glass, colored or white ceramic & plastics, rough or polished metal
- Steep slope compatibility thanks to Large Numerical Aperture (NA)
- Coaxial (no shadow effect)
- « Speckle » free
On CCS SERIES
Product |
Unit |
OP 300VM |
OP 300VM-90 |
OP 1 000 |
CL4-LWD |
OP 6 000 |
OP 8 000 |
OP 10 000 |
Order Code |
|
O3PS1400001 |
O3PS1400002 |
O3PS1400003 |
O3PS014LWD0 |
O3PS1400004 |
O3PS1400005 |
O3PS1400006 |
Measuring Range |
mm |
0.22 |
0.22 |
1 |
4 |
6 |
8 |
10 |
Working Distance |
mm |
5 |
4.4 |
23.9 |
40 |
28 |
39 |
66.9 |
Numerical Aperture |
|
0.5 |
0.5 |
0.45 |
0.36 |
0.39 |
0.295 |
0.2 |
Max. Slope Angle |
° |
±25 |
±25 |
± 24 |
± 21 |
± 22 |
± 16 |
± 11 |
Axial or Folded Model |
|
Axial |
Radial |
Axial |
Axial |
Axial |
Axial |
Axial |
Max. Linearity Error** |
µm |
±0.07 |
±0.07 |
± 0.2 |
0.3 |
± 0.5 |
± 0.6 |
± 0.8 |
Static Noise** |
nm |
25 |
25 |
50 |
110 |
200 |
350 |
600 |
Axial Resolution** |
µm |
0.15 |
0.15 |
0.3 |
0.66 |
1.2 |
2.1 |
3.6 |
Lateral Resolution |
µm |
3.2 |
3.2 |
2.2 |
4.3 |
6.25 |
16.5 |
25 |
Spot Size |
µm |
6.4 |
6.4 |
4.4 |
8.6 |
12.5 |
33 |
50 |
Photometric Efficiency |
|
34 |
19 |
10 |
25 |
49 |
133 |
138 |
Min. Measurable Thickness |
µm |
25 |
25 |
25 |
110 |
150 |
300 |
425 |
Length Diameter Weight |
mm mm g |
127 15 27 |
128 15 (17) 39 |
254.1 50 753 |
167.4 50 470 |
211 60 795 |
139 40 365 |
189 50 525 |
** With CCS electronics (PRIMA & OPTIMA+)
Product |
Unit |
OP 10 000-90 |
OP 12 000 |
NCTP |
OP 30 000 |
OP 35 000 |
OP 42 000 |
OP 100 000 |
Order Code |
|
O3PS1400007 |
O3PS1400010 |
O3PS1400009 |
O3PS1400008 |
O3PS1400011 |
O3PS1400012 |
O3PS1400014 |
Measuring Range |
mm |
10 |
12 |
20 |
30 |
35 |
42 |
100 |
Working Distance |
mm |
66.9 |
46 |
54.5 |
220 |
62 |
530 |
451 |
Numerical Aperture |
|
0.2 |
0.25 |
0.35/0.17 |
0.095 |
0.33 |
0.052 |
0.08 |
Max. Slope Angle |
° |
± 11 |
± 14 |
± 18/9 |
± 5 |
±17 |
±2.5 |
±5 |
Axial or Folded Model |
|
90° folded |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Max. Linearity Error** |
µm |
± 0.8 |
± 0.6 |
± 2 |
± 2.5 |
±2.2 |
±40 |
±16 |
Static Noise** |
nm |
600 |
380 |
1000 |
2000 |
1000 |
10000 |
5000 |
Axial Resolution** |
µm |
3.6 |
2.28 |
6 |
12 |
6 |
60 |
30 |
Lateral Resolution |
µm |
25 |
14 |
15 |
48 |
13 |
53 |
55 |
Spot Size |
µm |
50 |
32.5 |
30 |
96 |
26 |
106 |
110 |
Photometric Efficiency |
|
138 |
100 |
73 |
75 |
30 |
90 |
>150 |
Min. Measurable Thickness |
µm |
425 |
550 |
500 |
2000 |
1200 |
2500 |
2500 |
Length Diameter Weight |
mm mm g |
152 50 674 |
58.3 36 130 |
210 80/35 1025 |
168 59 405 |
300.3 80 2200 |
327 85 1700 |
348.9 120 4200 |
** With CCS electronics (PRIMA & OPTIMA+)
The chromatic confocal technology of OP series is suitable for a variety of applications in many fields:
- Automotive glass
- Glass containers and packaging industry
- Electrical vehicle industry (batteries)
- Applications for measuring roll-to-roll, transparent and non-transparent films (e.g. EV battery covers, flexible electronics)
- Electronics Industry (PCB)
- Semiconductor industry (silicon wafer)
- CCC industry
- Medical & microfluidic
- Micromechanics
- Aviation/Aerospace
- Watchmaking
- Robotics
OP series is available in more than ten versions as standard.
Customization and OEM design are available in circular diameter and square mechanical design.
Each OP optical head is compatible with all STIL ChromaPoint controllers such as ZENITH, CCS series, IRIX™ or LightMaster via a fiber optic connection.
BROCHURES AND MANUALS
Brochure | Data Sheet | |
---|---|---|
English |
STIL - General Catalogue: (13.23MB)
|
OP 300 VM & OP 300 VM-90: (881.05kB)
OP SERIES: (1.07MB) OP 1 000: (891.13kB) OP 6 000: (818.27kB) OP 8 000: (869.56kB) OP 10 000 & OP 10 000-90: (897.43kB) OP 12 000: (864.47kB) OP 30 000: (879.86kB) OP 35 000: (877.42kB) |
Japanese |
STIL - General Catalogue: (21.22MB)
|
- |
Simplified Chinese |
STIL - General Catalogue: (18.78MB)
|
- |