arrow-left-2arrow-left-3arrow-left-4arrow-leftchronodiggdown-arrow--lineardown-arrowearthenvelopefacebookfacebook_ (2)facebook_forward-arrowforwardgooglehomeico-downloadico-linkindustries--1industries--10industries--10_oldindustries--2industries--3industries--4industries--5industries--6industries--6_oldindustries--7industries--8industries--9linkedinmailmarkernewspaperpadlockpage-arrow-leftpage-arrow-rightpage-listpencilpinterestplay-buttonprintersearchsocial-diggsocial-facebooksocial-googlesocial-instagramsocial-linkedinsocial-pinterestsocial-twittersocial-youtubestartelephonetwittertwitter_user

Capteurs de dplacement

REDCROWN 2™

RedCrown2™ est la dernière génération de têtes crayon développées par Marposs, afin de fournir les plus hauts niveaux de performance métrologique en toute application.

La forme compacte, la précision de mesure, le design robuste, la facilité de serrage font de ce type de capteur l'élément de base pour créer des solutions personnalisées.

Capteurs de dplacement
DESCRIPTION

Red Crown2 est une ligne de têtes de mesure crayon à mouvement de bille à haute précision et différentes options de branchement. Elles sont indiquées dans de nombreuses applications et compatibles avec diverses interfaces.

La gamme permet également un niveau élevé de personnalisation en fonction des spécifications du client, afin de fournir des solutions optimales pour toute exigence.

La version Red Crown2 analogique, avec transducteur LVDT ou HBT, peut être utilisée avec les unités électroniques Marposs standard, ainsi qu'avec d'autres unités électroniques du commerce.

Ces dispositifs de mesure sont aussi disponibles sans connecteur (UNPLUGGED), afin que l'utilisateur puisse sélectionner le connecteur de son choix.

La version Red Crown2 USB comprend tous les systèmes électroniques d'interface du transducteur à l'intérieur du connecteur USB.

La mesure peut être affichée sur les unités électroniques Marposs (Nemo, Merlin, E9066) ou par connexion directe à un dispositif avec port USB, qui voit le Red Crown2 USB comme un port COM virtuel.

Marposs a développé un logiciel pour l'acquisition de la mesure (U-Com, Easy Acquisition et QSPC) ; une liste de commandes de protocole simples peut aussi être utilisée pour intégrer la mesure à des environnements de programmation de tierces parties.

Des mesures statiques et dynamiques peuvent être effectuées (fréquence max. d'échantillonnage : 1000 acquisitions/s).

La version digitalisée Digi Crown2, combinée au système Digi Crown Network, garantit de hauts niveaux de précision de mesure grâce aux données de linéarisation contenues dans la mémoire du connecteur. Le boîtier d'interface réseau peut lire la carte d'erreur et effectuer une compensation automatique.

Les informations stockées dans le connecteur garantissent une connexion au Système Digi Crown Network sans devoir programmer de tête individuelle (tampon et mesureur)

Des mesures statiques et dynamiques peuvent être effectuées (fréquence max. d'échantillonnage : 4000 échantillons/s).

Bien que conçues pour le système Digi Crown, les têtes Digi Crown2 peuvent être connectées aux dispositifs d'interface Marposs LVDT standard. 

Le nouveau RedCrown2 Smart numérise et linéarise le signal de mesure. Il est équipé d’une LED et d’un connecteur de traversée Ø8mm afin de simplifier l’application en garantissant une connexion rapide au réseau modulaire SmartNet.

AVANTAGES
  • Facile à installer
  • Fiable et robuste
  • Mesure d'une excellente précision
  • Entretien facile
  • Indiqué pour un usage en atelier (IP65)
  • Le contact interchangeable garantit que la tête s'adapte aux applications les plus variées.
  • Large choix de configurations personnalisables (spécifications et disposition)
  • Intégration facile à des systèmes de tiers grâce au logiciel spécifique
CARACTÉRISTIQUES TECHNIQUES

Pour toutes les caractéristiques techniques, veuillez consulter la brochure en section TÉLÉCHARGEMENT.

VERSIONS
  • Red Crown2 analogique, avec transducteur pont complet (LVDT) ou demi-pont (HBT), pour connexion à amplificateurs et interfaces Marposs, ou en version compatible avec amplificateurs d'autres fabricants.
  • Red Crown2 USB, avec connecteur USB pour branchement "plug&play" à ordinateurs commerciaux et industriels.
  • Digi Crown2, version digitalisée pour connexion au système Marposs Digi Crown Network.
  • RedCrown2 Smart, version digitalisée avec LED et connecteur de traversée Ø8mm pour connexion au réseau SmartNet.

Toutes les versions sont disponibles dans les modèles ci-après :

  • Avec connecteur câble axial ou radial
  • Cinq plages de mesure : 1mm, 2mm, 5mm,10mm et 20mm
  • Soft-Touch et Ultra-Soft-Touch avec très faible force de mesure pour surfaces et matériaux délicats
  • Actionnement/rétraction à ressort, pneumatique ou par vide
  • Avec différents connecteurs et longueurs de câble
  • OEM “private label” (marque propre FEO) : version avec graphismes personnalisés, marquage spécial, logo du client et emballage spécial
APPLICATIONS

Marposs fournit une gamme étendue de jeux de bras de mesure (Ama et Quick Block) et de composants (Quick Set) afin de créer des applications pour toute exigence.

  • Industrie automobile
  • Transmissions
  • Roulements
  • Récipients et emballage
  • Récipients en verre
  • Verre pour l'automobile 
  • Aérospatiale
  • Consommables électroniques
VIDEOS

Marposs présente Red Crown2 : la tête-crayon et solution pour vos mesures

L'association parfaite de gammes de mesures, de compatibilités électriques et d'extrême précision en versions analogique et numérique font de la tête-crayon Red Crown 2 la solution idéale pour tout fabricant d'appareils et de mesureurs.

Download

BROCHURES AND MANUALS

Brochure Manuel d'Utilization
Anglais REDCROWN 2: (2.24MB)
MANUAL GAUGING - Reference Guide: (10.16MB)
REDCROWN 2 Long Range (±10mm): (1.28MB)
REDCROWN 2: (1.85MB)
Italien REDCROWN 2: (2.23MB)
REDCROWN 2 Long Range (±10mm): (1.28MB)
REDCROWN 2: (1.85MB)
Allemande REDCROWN 2: (2.45MB)
REDCROWN 2 Long Range (±10mm): (1.29MB)
REDCROWN 2: (1.70MB)
Français REDCROWN 2: (2.21MB)
-
Japonais REDCROWN 2: (4.11MB)
MANUAL GAUGING - Reference Guide: (25.51MB)
-

DRAWINGS: STANDARD probe (with seal) ± 0.5 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F05-H05-D01: (89.97kB)
__F05-H05-D01: (204.81kB)
__F05-H05-D01: (181.24kB)
- SPRING - RADIAL CABLE - __FR05-HR05-RD01: (162.32kB)
__FR05-HR05-RD01: (13.37MB)
__FR05-HR05-RD01: (391.27kB)

DRAWINGS: STANDARD probe (with seal) ± 1 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F10-H10-D02: (169.45kB)
__F10-H10-D02: (2.38MB)
__F10-H10-D02: (417.03kB)
- SPRING - RADIAL CABLE - __FR10-HR10-RD02: (166.18kB)
__FR10-HR10-RD02: (2.55MB)
__FR10-HR10-RD02: (418.34kB)
- PNEUMATIC - AXIAL CABLE - __FPA10-HPA10-PAD02-FVA10-HVA10-PVAD02-VAD02: (102.52kB)
__FPA10-HPA10-PAD02-FVA10-HVA10-PVAD02-VAD02: (353.74kB)
__FPA10-HPA10-PAD02-FVA10-HVA10-PVAD02-VAD02: (217.57kB)
- PNEUMATIC - RADIAL CABLE - __FP10-HP10-PD02-FV10-HV10-PVD02-VD02: (180.59kB)
__FP10-HP10-PD02-FV10-HV10-PVD02-VD02: (2.67MB)
__FP10-HP10-PD02-FV10-HV10-PVD02-VD02: (461.79kB)

DRAWINGS: STANDARD probe (with seal) ± 2 mm long range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F21-H21: (173.85kB)
__F21-H21: (2.19MB)
__F21-H21: (428.72kB)
- SPRING - RADIAL CABLE - __FR21-HR21: (168.56kB)
__FR21-HR21: (2.87MB)
__FR21-HR21: (408.41kB)
- PNEUMATIC - AXIAL CABLE - __FPA21-HPA21-FVA21-HVA21: (114.93kB)
__FPA21-HPA21-FVA21-HVA21: (476.43kB)
__FPA21-HPA21-FVA21-HVA21: (251.92kB)
- PNEUMATIC - RADIAL CABLE - __FP21-HP21-FV21-HV21: (188.41kB)
__FP21-HP21-FV21-HV21: (3.07MB)
__FP21-HP21-FV21-HV21: (481.02kB)

DRAWINGS: STANDARD probe (with seal) ± 2.5 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F25-H25-D05: (174.97kB)
__F25-H25-D05: (2.15MB)
__F25-H25-D05: (421.81kB)
- SPRING - RADIAL CABLE - __FR25-HR25-RD05: (170.82kB)
__FR25-HR25-RD05: (2.82MB)
__FR25-HR25-RD05: (427.19kB)
- PNEUMATIC - AXIAL CABLE - __FPA25-HPA25-PAD05-FVA25-HVA25-PVAD05-VAD05: (109.30kB)
__FPA25-HPA25-PAD05-FVA25-HVA25-PVAD05-VAD05: (340.50kB)
__FPA25-HPA25-PAD05-FVA25-HVA25-PVAD05-VAD05: (235.48kB)
- PNEUMATIC - RADIAL CABLE - __FP25-HP25-PD05-FV25-HV25-PVD05-VD05: (186.55kB)
__FP25-HP25-PD05-FV25-HV25-PVD05-VD05: (2.99MB)
__FP25-HP25-PD05-FV25-HV25-PVD05-VD05: (475.61kB)

DRAWINGS: STANDARD probe (with seal) ± 5 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F50-H50-D10: (174.19kB)
__F50-H50-D10: (2.19MB)
__F50-H50-D10: (423.85kB)
- SPRING - RADIAL CABLE - __FR50-HR50-RD10: (169.09kB)
__FR50-HR50-RD10: (2.89MB)
__FR50-HR50-RD10: (425.00kB)
- PNEUMATIC - AXIAL CABLE - __FPA50-HPA50-PAD10-FVA50-HVA50-PVAD10-PVD10: (115.51kB)
__FPA50-HPA50-PAD10-FVA50-HVA50-PVAD10-PVD10: (466.80kB)
__FPA50-HPA50-PAD10-FVA50-HVA50-PVAD10-PVD10: (252.40kB)
- PNEUMATIC - RADIAL CABLE - __FP50-HP50-PD10-FV50-HV50-PVD10-VD10: (188.98kB)
__FP50-HP50-PD10-FV50-HV50-PVD10-VD10: (3.09MB)
__FP50-HP50-PD10-FV50-HV50-PVD10-VD10: (478.14kB)

DRAWINGS: STANDARD probe (with seal) ± 10 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F100-H100-D20: (178.30kB)
__F100-H100-D20: (13.09MB)
__F100-H100-D20: (438.52kB)
- SPRING - RADIAL CABLE - __FR100-HR100-RD20: (172.91kB)
__FR100-HR100-RD20: (14.77MB)
__FR100-HR100-RD20: (430.73kB)
- PNEUMATIC - AXIAL CABLE - __FPA100-HPA100-PAD20-FVA100-HVA100-PVAD20-PVD20: (140.21kB)
__FPA100-HPA100-PAD20-FVA100-HVA100-PVAD20-PVD20: (403.88kB)
__FPA100-HPA100-PAD20-FVA100-HVA100-PVAD20-PVD20: (319.55kB)
- PNEUMATIC - RADIAL CABLE - __FP100-HP100-PD20-FV100-HV100-PVD20-VD20: (198.00kB)
__FP100-HP100-PD20-FV100-HV100-PVD20-VD20: (15.27MB)
__FP100-HP100-PD20-FV100-HV100-PVD20-VD20: (529.41kB)

DRAWINGS: SOFT TOUCH probe (without seal) ± 0.5 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F05L-H05L-D01L: (97.43kB)
__F05L-H05L-D01L: (489.67kB)
__F05L-H05L-D01L: (207.00kB)
- PNEUMATIC - AXIAL CABLE - __FPA50L-HPA50L-PAD10L-FPVA50L-HPVA50L-PVAD10L: (92.03kB)
__FPA50L-HPA50L-PAD10L-FPVA50L-HPVA50L-PVAD10L: (165.84kB)
__FPA50L-HPA50L-PAD10L-FPVA50L-HPVA50L-PVAD10L: (186.30kB)
- PNEUMATIC - RADIAL CABLE - __FP50L-HP50L-PD10L-FPV50L-HPV50L-PVD10L: (167.49kB)
__FP50L-HP50L-PD10L-FPV50L-HPV50L-PVD10L: (9.36MB)
__FP50L-HP50L-PD10L-FPV50L-HPV50L-PVD10L: (423.31kB)

DRAWINGS: SOFT TOUCH probe (without seal) ± 1 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F10L-H10L-D02L: (173.64kB)
__F10L-H10L-D02L: (8.56MB)
__F10L-H10L-D02L: (441.13kB)
- SPRING - RADIAL CABLE - __FR10L-HR10L-RD02L: (167.33kB)
__FR10L-HR10L-RD02L: (9.23MB)
__FR10L-HR10L-RD02L: (437.22kB)
- PNEUMATIC - AXIAL CABLE - __FPA10L-HPA10L-PAD02L-FPVA10L-HPVA10L-PVAD02L: (100.11kB)
__FPA10L-HPA10L-PAD02L-FPVA10L-HPVA10L-PVAD02L: (263.45kB)
__FPA10L-HPA10L-PAD02L-FPVA10L-HPVA10L-PVAD02L: (437.51kB)
- PNEUMATIC - RADIAL CABLE - __FP10L-HP10L-PD02L-FPV10L-HPV10L-PVD02L: (174.42kB)
__FP10L-HP10L-PD02L-FPV10L-HPV10L-PVD02L: (9.34MB)
__FP10L-HP10L-PD02L-FPV10L-HPV10L-PVD02L: (458.79kB)

DRAWINGS: SOFT TOUCH probe (without seal) ± 2 mm long range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F21L-H21L: (165.15kB)
__F21L-H21L: (12.91MB)
__F21L-H21L: (410.97kB)
- SPRING - RADIAL CABLE - __FR21L-HR21L: (159.44kB)
__FR21L-HR21L: (14.28MB)
__FR21L-HR21L: (393.62kB)
- PNEUMATIC - AXIAL CABLE - __FPA21L-HPA21L-FPVA21L-HPVA21L: (91.60kB)
__FPA21L-HPA21L-FPVA21L-HPVA21L: (148.60kB)
__FPA21L-HPA21L-FPVA21L-HPVA21L: (186.18kB)
- PNEUMATIC - RADIAL CABLE - __FP21L-HP21L-FV21L-HV21L: (165.69kB)
__FP21L-HP21L-FV21L-HV21L: (14.60MB)
__FP21L-HP21L-FV21L-HV21L: (417.51kB)

DRAWINGS: SOFT TOUCH probe (without seal) ± 2.5 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F25L-H25L-D05L: (177.63kB)
__F25L-H25L-D05L: (8.66MB)
__F25L-H25L-D05L: (442.44kB)
- SPRING - RADIAL CABLE - __FR25L-HR25L-RD05L: (172.73kB)
__FR25L-HR25L-RD05L: (9.40MB)
__FR25L-HR25L-RD05L: (445.18kB)
- PNEUMATIC - AXIAL CABLE - __FPA25L-HPA25L-PAD05L-FPVA25L-HPVA25L-PVAD05L: (101.28kB)
__FPA25L-HPA25L-PAD05L-FPVA25L-HPVA25L-PVAD05L: (273.00kB)
__FPA25L-HPA25L-PAD05L-FPVA25L-HPVA25L-PVAD05L: (220.47kB)
- PNEUMATIC - RADIAL CABLE - __FP25L-HP25L-PD05L-FPV25L-HPV25L-PVD05L: (177.28kB)
__FP25L-HP25L-PD05L-FPV25L-HPV25L-PVD05L: (9.47MB)
__FP25L-HP25L-PD05L-FPV25L-HPV25L-PVD05L: (455.63kB)

DRAWINGS: SOFT TOUCH probe (without seal) ± 5 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F50L-H50L-D10L: (164.93kB)
__F50L-H50L-D10L: (8.35MB)
__F50L-H50L-D10L: (406.22kB)
- SPRING - RADIAL CABLE - __FR50L-HR50L-RD10L: (158.99kB)
__FR50L-HR50L-RD10L: (9.08MB)
__FR50L-HR50L-RD10L: (406.34kB)

DRAWINGS: SOFT TOUCH probe (without seal) ± 10 mm range

- Drawing [PDF] - - Drawing [STEP] - - Drawing [DWG] -
- SPRING - AXIAL CABLE - __F100L-H100L-D20L: (163.71kB)
__F100L-H100L-D20L: (13.01MB)
__F100L-H100L-D20L: (411.12kB)
- SPRING - RADIAL CABLE - __FR100L-HR100L-RD20L: (158.40kB)
__FR100L-HR100L-RD20L: (17.68MB)
__FR100L-HR100L-RD20L: (403.09kB)
- PNEUMATIC - AXIAL CABLE - __FPA100L-HPA100L-PAD20L-FVA100L-HPVA100L-PVAD20L: (93.31kB)
__FPA100L-HPA100L-PAD20L-FVA100L-HPVA100L-PVAD20L: (145.67kB)
__FPA100L-HPA100L-PAD20L-FVA100L-HPVA100L-PVAD20L: (190.27kB)
- PNEUMATIC - RADIAL CABLE - __FP100L-HP100L-PD20L-FPV100L-HPV100L-PVD20L: (162.34kB)
__FP100L-HP100L-PD20L-FPV100L-HPV100L-PVD20L: (14.94MB)
__FP100L-HP100L-PD20L-FPV100L-HPV100L-PVD20L: (417.32kB)
Close
Close

Informations requises

Insert your first name
Insert your last name
Insert the company name
Saisissez votre adresse électronique

Pour que le message puisse être transmis au service concerné, veuillez sélectionner le champ d'application dans la liste ci-dessous :

Insert your message

Avant d'envoyer le formulaire, veuillez lire avec attention la note d'information sur le traitement de vos données à caractère personnel, fournie conformément au Règlement UE 679/2016. .

Please accept the privacy policy
Top CONTACTS